1.0 AIM
To provide standard operating procedure for calibration, operation and cleaning of weighing
balance.
2.0 SCOPE
Production Department.
3.0 AREA OF OPERATION
Store Department.
4.0 RESPONSIBILITY
Operator concerned
5.0 ACCOUNTABILITY
Stores Incharge.
6.0 CALIBRATION
6.1 Check the clenliness of the balance & weighing area.
6.2 For calibration of the balance standard weights which are calibrated are used.
6.3 Level the balance properly.
6.4 Select the standard weights according to the capacity of balance i.e.
lower weight, middle weight, & upper weight of a balance capacity.
6.5 Switch ON the balance adjust to "0".
6.6 Place standard weight one by one on the weighing pan & record the reading in the balance calibration record.
6.7 Check that the observed weights are with in the limits. Acceptable limit is _ñ_ 0.1%.
7.0 REVIEW DATE
After 2 years or when procedure is changed.
No comments: