CLEANING PROCEDURE FOR AF 40 CAPSULE AUTO FILLING MACHINE
1. Objective:
To provide a standard cleaning procedure of AF 40 Capsule filling machine and its accessories.
2. Scope:
2.1 This procedure covers dismantling, cleaning and assembling of AF 40 capsule filling machine and its accessories.
2.2 Provides cleaning procedure if the cleaning validity not exceed 48 hours.
3. Responsibility:
¯ Operator.
¯ Chemist.
¯ Production Manager.
¯ Q.A. Manager.
4. Procedure:
4.1 Switch off the mains and close the air valve. Dismantle the hopper, augers, rotating table top, needle plates.
4.2 Wash the hopper with raw water followed by 0.1% sodium lauryl sulphate.
4.3 Wash the auger, rotating table top, needle plates with 0.5%v/v Teepol solution.
4.4 Rinse with DM water.
4.5 Clean the entire machine with wet cloth and then by dry cloth.
4.6 Put the status label as “Cleaned” with date and time.