Flipkart

Wednesday, November 23, 2011

CLEANING PROCEDURE FOR MASS MIXER



1.  Objective:
To provide a standard cleaning procedure of  mass mixer  and its accessories.

2.  Scope:
2.1      This procedure covers dismantling and cleaning of mass mixer  and its accessories.
2.2      Provides cleaning procedure if the cleaning validity not exceed 48 hours

3.  Responsibility:
¯  Operator.
¯  Chemist.
¯  Production Manager.
¯  Q.A. Manager
4.  Procedure:
4.1      Switch off the main and close the material discharge hole .
4.2      Open the lid of themass mixer. Dismantle the propeller blade .
4.3      Wash the dismantled accessories with 0.5% (v/v) Teepol solution, 0.1 % Sodium Lauryl Sulphate by using nylon brush and finally rinse with DM water.
4.4      Fill raw water upto ¼ of the MM and wash with nylon brushes to remove powder of previous product.
4.5      Drain the washed water through discharge hole, wash with 0.5% (v/v) Teepol solution and 0.1 % Sodium Lauryl Sulphate and finally rinse with DM water.
4.6      Wipe all machine parts with wet cloth and then with dry cloth.
4.7      Collect the washed water and send it to Quality Assurance to check the presence of any residual moiety.
4.8      Assemble the dismantled parts in it, after the approval of Quality Assurance.
4.9      Ensure that the discharge hole & panel board have been washed thoroughly.
4.10   Put the status label as “Cleaned” with date & time and allow for drying.

Wednesday, November 16, 2011

CLEANING PROCEDURE FOR FLUIDISED BED DRIER


1.    Objective:
To provide standard cleaning procedure of  Fluidized bed drier and its accessories.
2.    Scope:
2.1      This procedure covers dismantling and cleaning of Fluidized bed drier and its accessories.
2.2      Provides cleaning procedure if the cleaning validity not exceed 48 hours.
3.    Responsibility:
¯  Operator.
¯  Chemist.
¯  Production Manager.
¯  Q.A. Manager.
4.   Procedure:
4.1      Switch off the main supply.
4.2      Dismantle the product chamber, Retard chamber, prefilter and finger bag strap.
4.3      Wash the fixed chamber & dismantled accessories with 0.5% (v/v) Teepol solution and product chamber should be washed with 0.1% Sodium Lauryl Sulphate by using nylon brush. Finally rinse with DM water.
4.4      Wipe whole machine with wet cloth and then with dry cloth.
4.5      Collect the washed water and send it to Quality Assurance to check the presence of any residual moiety.
4.6      Assemble the dismantled parts in it, after the approval of Quality Assurance.
4.7      Put the status label as “Cleaned” with date & time and allow for drying.


Monday, November 7, 2011

CLEANING PROCEDURE FOR DRY SYRUP FILLING AND SEALING MACHINE


1.    Objective:
To provide standard cleaning procedure of Dry Syrup Filling & Sealing Machine & its accessories.
2.    Scope:
2.1      This procedure covers dismantling cleaning and assembling of Dry Syrup Filling & Sealing Machine and its accessories.
2.2      Provides cleaning procedure if the cleaning validity not exceed 48 hours.
3.    Responsibility:
¯  Operator.
¯  Chemist.
¯  Production Manager.
¯  Q.A.Manager.
4.    Procedure:


4.1      Wash all parts of the Dry Syrup Filling & Sealing machine with 0.5%v/v Teepol solution and rinse with DM water.






4.2      After that clean  the machine with dry cloth.


4.3      Collect the washed water and send it to Quality Assurance to check the presence of any residual moiety.


4.4      After the approval of Quality Assurance, Put the status label as “Cleaned” and allow for drying.

Thursday, November 3, 2011

CLEANING PROCEDURE FOR DE FOILLING MACHINE


1.    Objective:
To provide standard cleaning procedure of De Foilling Machine & its accessories.
2.    Scope:
2.1      This procedure covers dismantling cleaning and assembling of De Foilling Machine and its accessories.
2.2      Provides cleaning procedure if the cleaning validity not exceed 48 hours.
3.    Responsibility:
¯  Operator.
¯  Chemist.
¯  Production Manager.
¯  Q.A.Manager.
4.    Procedure:

4.1      Remove all the previous products ( tablets,capsules,empty strips) from the De Foilling machine.

4.2      Clean the machine and it parts by clean musclin cloth.


4.3      Then clean the machine by IPA.

4.4      Then dry it properly and then switch on the De Foilling machine.

4.5      After that start   the machine.